Reviewing plans
When looking at 2D architectural floor plans, you are essentially looking at a slice through your home at about 1.2m above the floor. To catch errors before they are set in concrete, look beyond the rooms and focus on functionality, flow, and furniture.
Ground floor, the public and structural hub
The ground floor is where daily routines live. Beyond the room labels, look at how spaces connect and whether the layout will support how your household actually moves through a day.
Indoor-outdoor flow. Look at the door swing of your main alfresco or backyard doors. If they swing inwards, they eat up living space. If they are sliding or bi-fold, check where the 'stack' sits so it doesn't block a walkway.
The grocery path. Trace your finger from the garage or carport to the pantry. If you have to walk through three doors and around a kitchen island, the layout is inefficient.
Sightlines from the kitchen. Imagine standing at the kitchen sink. What can you see? You generally want a line of sight to the backyard (to watch children) or the TV and living area, but not a direct line of sight into a bathroom or laundry.
The drop zone. Look for a dedicated space near the entry for shoes, bags, and mail, often called a Mudroom or Joinery Niche. Without this on the plan, clutter will migrate to your kitchen bench.
Plumbing alignment. If you are adding a bathroom upstairs, try to stack it directly above the ground floor laundry or kitchen to save thousands in plumbing costs.
First floor, the private sanctuary
First floors are where comfort details matter most. Bedrooms, acoustics, and orientation errors are expensive to fix post-construction and hard to live with long-term.
Staircase safety and bulk. Check the 'Up' arrow. Look at what is under the stairs on the ground floor, is it wasted space or a powder room or storage? Upstairs, ensure the landing is as small as possible to maximise bedroom sizes. Also check the riser and going dimensions are consistent and within code (risers 115 to 190mm, goings 240 to 355mm). Non-compliant stairs are a costly rebuild.
Window orientation, the heat rule. Check the North point. Large west-facing windows upstairs will turn bedrooms into saunas in an Australian summer. Look for smaller windows or external shading on the west elevation.
Furniture clearance. Do not trust the little 'bed' symbols the architect drew. Get the dimensions of your actual bed (e.g., King size) and draw it to scale. Is there at least 900mm of walking space on both sides? Can you still open the wardrobe doors?
Privacy and overlooking. Check the window heights (indicated by SIL or Sill Height). If a window is low, can neighbours see straight into your shower? You may need Obscure Glazing or Awnings marked on the plan. Note also that for bedroom windows, where the floor is 2m or more above the ground outside and the lowest part of the opening is below 1700mm from the floor, the opening must be restricted so a 125mm sphere cannot pass (or fitted with a compliant fall-prevention screen that resists a 250N outward force). For rooms other than bedrooms, this protection is required only where the floor is 4m or more above the surface beneath. Check this is marked on the plan.
Acoustics. Is the master bedroom sharing a wall with a noisy area such as the stairs or a kid's playroom? Look for a 'staggered stud' or 'acoustic insulation' note on that specific wall.
Universal red flags, both floors
Door conflicts. Look for door clashes, where two doors hit each other if opened at the same time, such as an ensuite door hitting a bedroom door.
Switch placement. In the electrical overlay, ensure light switches are on the latch side of the door. You don't want to walk into a dark room and have to reach behind the door to find the switch.
Ceiling heights. Look for CH (Ceiling Height) markers. Standard is 2400mm; for a premium feel you want 2700mm on the ground floor. Check if there are any bulkheads (dropped sections of ceiling) that might ruin the look of your kitchen cabinets.
The void. If your plan has a Double Height Void, check the acoustics. Sound travels perfectly up a void, if someone is watching TV downstairs, it will be loud in the upstairs bedrooms.
Balustrade and barrier compliance. Any drop of 1m or more (landings, the void edge, or a balcony) needs a barrier at least 1m high. For stairs and ramps the required barrier or handrail height is at least 865mm above the stair nosings or ramp floor. Openings must be too small to pass a 125mm sphere. Where the possible fall exceeds 4m, the barrier must also have no climbable horizontal elements between 150mm and 760mm. Confirm balustrades are shown on the plan.
Plan abbreviation reference
Architects use shorthand to save space on the plan so they can fit dimensions. Use the search or filter below to find any code quickly.
Walk-In Robe / Walk-In Linen
Walk-In Pantry
Ensuite
Water Closet (Toilet)
Laundry
Powder Room
Built-In Robe
A recessed shelf, usually in a shower or for a TV
General Purpose Outlet (standard power point). DGPO = double
Above Finished Floor, used for heights, e.g. GPO at 1100mm AFF
Downpipe, check these are not placed in the middle of a window view
Ceiling Height or Finished Ceiling Level
Smoke Detector (or Sliding Door, check the context)
Hot Water Service or Unit
Master Switch Board, usually on an external wall
Obscure Glazing, frosted glass for privacy, common in bathrooms
Double Glazing
Cavity Sliding Door, a door that slides into the wall pocket
Volatile Organic Compounds, noted in paint specs. You want Low VOC
Verify In Field, a warning: don't trust this measurement; measure the real wall before building cabinets
Finished Floor Level, the height of the actual floor surface (e.g. top of tiles). Crucial for checking step-downs to a balcony
Relative Level, the height of a point relative to a fixed datum or sea level (AHD). Used to check Council height limits
Natural Ground Line, the original slope of the land before excavation. Helps assess how much cut-and-fill is required
Sill Height, the height of the bottom of a window from the floor. Low sills can compromise privacy
Kitchen, ergonomics and clearances
The kitchen is the most scrutinised room in a renovation and the most expensive to get wrong. These are the measurements and relationships that determine whether a kitchen actually works.
Appliance opening zones
You must account for the arc of a door or drawer when fully open, it claims floor space that cannot be used simultaneously.
600–700mm
arc into walkway
Dishwasher arc
Ensure 1,000mm clearance between dishwasher and the opposite island or bench when the door is fully open.
450–500mm
door drops downward
Oven door drop
Allow at least 1,000mm of clearance in front so you can step back safely when removing a hot tray.
20–50mm
clearance on all sides
Fridge breathing room
20–30mm on sides, 50mm at top and rear. Without this, the compressor overheats and runs continuously.
100–300mm
filler beside fridge
Fridge door swing
Without a filler gap next to a wall, the door cannot open past 90° and crisper drawers cannot be pulled out.
30–40mm
handle protrusion
Handle depth
Every handle adds 30–40mm to a cabinet's effective depth. Add this to all walkway and clearance calculations.
Critical measurements at a glance
Island bench and seating ergonomics
300mm
Standard bench overhang
Leg room at 900mm bench height.
450mm
Dining height overhang
Leg room at 750mm dining height.
600mm
Width per stool
A 2400mm island seats 4 comfortably; 1800mm is tight for 3.
Kitchen review checklist
Main walkways
At least 1050mm for one cook; 1200mm for two cooks working simultaneously.
Island seating overhang
At least 300mm of leg overhang at standard bench height (900mm), or 450mm at dining height (750mm). Allow 600mm width per stool. Note that overhangs greater than 300mm may require additional structural support, check with your kitchen supplier for the maximum unsupported span for your chosen benchtop material.
Dishwasher clearance
At least 1000mm between the dishwasher face and the opposite bench to allow loading and unloading, though 1200mm is the recommended ideal where space allows.
Fridge door swing
Fridge doors must open past 90° to allow internal crisper drawers to slide out fully. Allow 100mm–300mm of filler space if the fridge is adjacent to a wall.
Oven landing zone
A bench space within 1200mm of the oven to set down hot trays safely.
Rangehood height
At least 650mm from the cooktop surface to the rangehood for new gas installations (AS/NZS 5601.1:2022), unless the appliance or rangehood instructions require more. For electric or induction, follow the rangehood manufacturer's specified clearance, commonly around 600mm. Always cross-check your specific cooktop and rangehood manuals, as manufacturers may specify greater clearances.
Sink prep space
At least 600mm of bench on one side of the sink and 450mm on the other. This is a best practice guideline rather than a codified standard, but is widely recommended by Australian kitchen designers for comfortable food preparation.
Dining buffer
At least 1200mm between the island stools and the dining table so people can move past while both seats are occupied.
Corner dead zones
Check that drawers won't hit the handles of perpendicular cabinets when opened. A blind corner panel or filler strip (min 50mm) is required at every 90-degree junction.
Workflow trace
Imagine moving a pot of boiling pasta from the stove to the sink. Is there an island in the way? Is the distance more than three steps?
Kitchen red flags to avoid
Related content
Renovation Roadmap
Upgrade to unlock everything
Upgrade to the full Renovation Roadmap membership for the complete guide and full toolkit.
Copyright © 2026 Renovation Roadmap. Unauthorised use and/or duplication of this material without express and written permission from this site’s author and/or owner is strictly prohibited.


